Call us 24/7+86 18150137010
Welcome to Industrial Control Trading Co., Ltd. Email: itadcs@163.com Whatsapp:+86-17750137010
Call us 24/7+86 18150137010

EMERSON KJ3242X1-BK1 12P4711X042 S-Series H1 Card

KJ3242X1-BK1 S-Series H1 Card

Hazardous Atmosphere

II 3G Ex ec IIC Gc

FM19ATEX0173U

IECEx FMG 19.0019U

FM21UKEX0017U

II 3G Ex nA nL IIC Gc

Nemko 10ATEX3225U

IECEx NEM 10.0019U

CL. I Div. 2 GP. A,B,C,D

CL. I Zone 2 AEx/Ex ec IIC Gc

FM17US0286U

FM17CA0145U

Power Specifications

Local Bus Power

Fieldbus Power

12 VDC at 300 mA

9 to 32 VDC at 12 mA/Port

Environmental Specifications

Ambient

Temperature

Shock

Vibration

Airborne

Contaminants

Relative Humidity

Terminal Block key

KJ3242X1-BK1

Position  -40°C to +70°C

10g ½ Sinewave for 11msec

1mm Peak to Peak from 2 to 13.2Hz;

0.7g from 13.2 to 150Hz

ISA-S71.04 –1985 Airborne

Contaminants Class G3

5 to 95% Non-Condensing

Note: Refer to the product label for serial number

and location and date of manufacture.

Warning: This product has specific instructions for

installation, removal and operation in hazardous

areas. Refer to document 12P5404 “DeltaV™ S

Series Digital Automation System Zone 2 Installation

Instructions”.  Other installation instructions are

available in the “DeltaV™ S-Series and CHARMs

Hardware Installation” manual.

Removal and Insertion

Field power supplied to this device, either at the field

terminal or as bussed field power through the

Carrier, must be removed before removing or

connecting the device.

This unit cannot be removed or inserted with system

power energized.

For “nL” installation, an I/O loop assessment must

be completed on all energy-limited nodes.

A rotary keying system ensures compatibility

between I/O cards and terminal blocks after

installation is complete. The terminal block must

have the keys set for the I/O card with which it is

used.

Maintenance and Adjustment

This unit contains no user serviceable parts and

should not be disassembled for any reason.

Calibration is not required.

KJ3242X1-BK1

EMERSON 960132-01 FX-316 Positioning Servo Drive 230 VAC

EMERSON  960132-01 FX-316 Positioning Servo Drive 230 VAC

CSL Part Number: 24202

Category: AC Motor Controls

Manufacturer: Emerson

Manufacturer Part Number: 960132-01

Series: FX Positioning Drive

Also Known As(AKA): FX-316

Engineered for precision automation, the EMERSON FX-316 960132-01 control module delivers reliable performance in motor control,

system synchronization, and process monitoring applications.

This industrial-grade component maintains operational stability in harsh environments while supporting seamless integration with existing automation infrastructures.

FX-316 960132-01

Attribute    Specification

Manufacturer    EMERSON

Model Number    FX-316 960132-01

Operating Voltage    220 V

Output Frequency    56 kHz

Certification    Industrial Standards Compliance

960132-01 FX-316

EMERSON I26 05 L   MOTOR
EMERSON Control Techniques M700-054 00270   Unidrive, FOR PARTS/ REPAIR
EMERSON 36A8449X012 / 36A8449X012
FX-340 EMERSON FX-340 POSITIONING SERVO   DRIVE 960133-01 REV. B1/B3
EMERSON 275-0003-0500 / 27500030500
Emerson/Bristol Babcock 396563-04-0   ControlWave Micro Ser. A. CPU module – NEW
NEW Emerson 8140-DI-AC 16-Ch 115VAC   Isolated Sinking Digital Input Module
1 Emerson (Motion Control)   MGE-316-CONS-0000 Servo Motor 4000RPM 230VAC
Control Techniques Emerson DIN1220075A   0.75kW
EMERSON DXE-208CB SERVO MOTOR 240VAC 3A   .47HP, 960106-13 A1 鈿★笍馃嚭馃嚫 SHIP+WARRANTY
EMERSON DELTAV KJ2005X1-BK1 SX CONTROLLER   12P4688X REV S REV E
Emerson Control Techniques MD-404-00-000   Servo Drive Module
EMERSON PSM-A10 COMMUNICATION POWER   MONITORING MODULE Spot Goods DHL/Fedex
NEW EMERSON DeltaV – RS3 I/O INTERFACE   MODULE 12P2740X042 Rev D
EMERSON RM100-EM-8SFP 12P4477X022 NSMP
EMERSON ROC-800 REMOTE OPERATIONS   CONTROLLER KEYPAD DISPLAY NEW IN BOX !!
 Original MP700A4R Emerson Inverter Brand NEW   In Box MP700A4R US STOCK
EMERSON SC940-001 / SC940001 (NEW IN BOX)
Tyco/Emerson Ovation Relay Assembly   5A26458G05 Rev. 09
EMERSON CONTROL TECHNIQUES UNIDRIVE   M600-044 00150 A

EMERSON KJ4006X1-BD1 Interface Terminal Block

Hazardous Atmosphere

II 3G Ex ec IIC Gc

FM19ATEX0173U

IECEx FMG 19.0019U

FM21UKEX0017U

CL. I Div. 2 GP. A,B,C,D

CL. I Zone 2 AEx/Ex ec IIC Gc

FM17CA0145U

FM17US0286U

Power Specifications

Field Power

35 VDC at 1 A

Environmental Specifications

KJ4006X1-BD1

Ambient

Temperature

Shock

Vibration

Airborne

Contaminants

Relative Humidity

Terminal Block

Key Position -40°C to +70°C

10g ½ Sinewave for 11msec

1mm Peak to Peak from 2 to 13.2Hz;

0.7g from 13.2 to 150Hz

ISA-S71.04 –1985 Airborne

Contaminants Class G3

5 to 95% Non-Condensing

Set according to I/O card installed

Note: Refer to the product label for serial number

and location and date of manufacture.

Warning: This product has specific instructions for

installation, removal and operation in hazardous

areas. Refer to document 12P5404 “DeltaV™ S

Series Digital Automation System Zone 2 Installation

Instructions”.  Other installation instructions are

available in the “DeltaV™ S-Series and CHARMs

Hardware Installation” manual.

Removal and Insertion

Terminals Block can be added or removed with

System Power applied only when no I/O Card is

installed, and no field wiring is connected to the

terminal.

A rotary keying system ensures compatibility

between I/O cards and terminal blocks after

installation is complete. The terminal block must

have the keys set for the I/O card with which it is

used.

Maintenance and Adjustment

This unit contains no user serviceable parts and

should not be disassembled for any reason.

Calibration is not required.

EMERSON 1C31181G01 module

EMERSON 1C31181G01 module

First, the importance of industrial equipment installation

In modern industrial production, various equipment and machines are widely used in various fields, such as manufacturing, energy industry, chemical industry and so on.

The installation of industrial equipment is directly related to production efficiency and product quality.

Proper installation and commissioning of good equipment can ensure the stable operation of the production line, improve production efficiency and product quality,

reduce maintenance costs, and ensure the safety of employees.

Second, the steps of industrial equipment installation

Preparation: Before the installation of industrial equipment, it is necessary to carry out adequate preparation work.

This includes the tools and equipment required for installation, cleaning and preparation of the installation site, and making installation plans and schedules.

1C31181G01

1C31181G01

EMERSON 396358-01-2 / 396358012

Emerson FP20-6TX1MM1TX Delta V Smart Switch, 8-Port Total, 24VDC, RJ45

EMERSON DXM-208CB / DXM208CB

EMERSON 8712-0507-0032 / 871205070032

EMERSON MMI-20013514 / MMI20013514

Emerson CT frequency converter SP1403 new

NEW Emerson KJ3209X1-BA1 DO Module 8 Channel 120/230VAC

EMERSON MVME-162-510A / MVME162510A

NEW Emerson Nidec SK2401 Inverter

Emerson Control Wave Micro CPU Module Ethernet 396563-16-3S D 16MB Series E

Emerson Control Techniques Unidrive UNI2402

EMERSON EXPLOSION PROOF PRESSURE TRANSMITTER 2088G2S22A1M5E5Q4S5P0054

EMERSON KL3001X1-BA1 NSMP

NEW Emerson CT UNI1403 Inverter

Control Techniques Unidrive UNI1403 UNI 1403 Emerson,

EMERSON 1120-4 / 11204

EMERSON 413-064-000 / 413064000

NEW Emerson 8140-DI-AC-03 Rev A 16-Ch 115VAC Isolated Digital Input Module

NEW! Emerson 2400-8000 Focus 1 Adjustable Voltage DC Drive 1/4 – 2HP馃嚭馃嚫. BC

EMERSON 396608-07-8 / 396608078

Emerson SD-1 Mentor II Regen SCR Power Module Heatsink Thyristor Rectifier Stack

NEW Emerson Nidec DST1405B Inverter

EMERSON CE4003S2B6 I/O Termination Block

EMERSON CE4003S2B6  I/O Termination Block

Brand/ Manufacturer: EMERSON
Manufacturer Part Number:

CE4003S2B6
Additional Information:

Standard I/O Termination Block
Basic  Info

Product Name:Emerson

Material:CE4003S2B6

Warranty:1 Year

CE4003S2B6

EMERSON PLC Module VE4017P0 (New In Sealed Packaging)

dulo de Carregamento Emerson HD11010-3A

EMERSON RT420S / RT420S

NEW EMERSON LSN20 DELTAV 6-PORT SAFETY NETWORK SWITCH LSN20-6TX2MM-ES

Emerson epro MMS 6250 MMS6250 9100-00057 Machine Monitoring System -Unused/Original Box-

NEW EMERSON DELTAV KJ2003X1-BB1 / 12P3439X012 CONTROLLER MD+ PLUS

NEW Emerson KJ3204X1-BA1 DO Module 32Ch 24VDC w/ Terminal Block

EMERSON AXIMA-02-00 DRIVE

EMERSON CONTROL TECHNIQUES UNIDRIVE M700-054 00300 A

NIB Emerson Delta V KJ1501X1-BC3 VE5009 Power Supply Original Sealed Static Bag

EMERSON CT SP2402 Inverter Drive

1X NEW Emerson CT SP2401 Inverter 5.5/7.5 KW

EMERSON CT SK3401 AC Variable Frequency Drive

Rosemount Emerson RM1040 Delta V Smart Switch

EMERSON DELTAV KJ2005X1-BK1 SX CONTROLLER 12P4688X REV S REV E

Emerson Control Techniques SK2403 Inverter

EMERSON Power One WH5-2FF Ovation Power Supply Module 24VDC 12A/8A Output New

Emerson Digital System Interface Board 6180-4020

1x NEW Emerson Prism AC Servo Drive w/Cover & Controls PN2950-8003 5HP 480V 8.4A

NEW EMERSON DeltaV KJ3004X1-BA1 Fieldbus H1 Module 600mA 12VDC

NEW Emerson 8140-DI-AC 16-Ch 115VAC Isolated Sinking Digital Input Module

EMERSON H300 HVAC VFD 30HP W CONTROL PANEL P40030NB23 H300-064 00480 460V 38A

New Rosemount Analytical 1056-03-20-30-AN Emerson Analyzer as photo

ASCO Emerson Series 510 Surge Protection Part# 510YC08ANCL1S ASCO Power Techno

Emerson INVERTER SKB3400055 refurbished FREE EXPEDITED SHIPPING

1PC Emerson Control Techniques SP1406 Inverter New

EMERSON 5 ROW P2 ADAPTER TRANSITION MVME7616E-011 – NOS

Emerson DST1405 servo drive Tested In Good Condition

Emerson Control Techniques Commander Model: SK2403-029-1/ Freq In/Out: 50/

NEW Emerson Nidec SKBD200110 Inverter

EMERSON KJ4001X1-CK1 40-Pin Mass Termination Block

KJ4001X1-CK1  40-Pin Mass Termination Block

Hazardous Atmosphere

II 3 G

EEx nA IIC T4

Nemko No. 02ATEX431U

Power Specifications

Input

30 VDC at 1 A per channel

Environmental Specifications

Ambient Temperature 0 to 70 oC

Shock

Vibration

Airborne

Contaminants

Relative Humidity

10 g half-sine wave for 11 ms

1 mm peak to peak from 2 to

13.2 Hz; 0.7 g from 13.2 to 150 Hz

ISA-S71.04 –1985 Airborne

Contaminants Class G3

5 to 95% Non-Condensing IP 20

Rating

Note: Refer to the product label for serial number

and location and date of manufacture. Refer also to

the wiring diagram on the left side of the card.

Warning: This product has specific instructions for

installation, removal and operation in hazardous

areas. Refer to document 12P2046. DeltaV 

Scalable Process System Zone 2 Installation

Instructions. Other installation instructions are

available in the Installing Your DeltaV Automation

System manual.

Removal and Insertion

A rotary keying system ensures compatibility

between I/O cards and terminal blocks after

installation is complete. This terminal block must

have the keys set for the I/O card it is to be used

with.

KJ4001X1-CK1

Maintenance and Adjustment

This unit contains no user-serviceable parts and

should not be disassembled for any reason.

Calibration is not required.

NEW Emerson Rosemount 2051 Series Flow Meter Pressure Transmitter R2051C4789580

1PC NEW EMERSON Inverter SP4403 Via DHL / FedEX

Emerson T-60 Operator Interface Terminal Tested Clean 960103-01

1PC NEW EMERSON Inverter ES3401 Via DHL / FedEX

NEW Emerson Nidec SKBD200150 Inverter

Emerson BLM-8500-4 Servo Motor 460V 3000rpm BLM85004

NEW Emerson 8140-DI-AC-03 Rev A 16-Ch 115VAC Isolated Digital Input Module

NEW Emerson Nidec SK3402 Inverter

NEW Emerson/GE FANUC Output Module IC694MDL916

NEW Emerson Nidec DST1401 Inverter

1PC New Emerson SKB3400055 With Warranty Free Tax

New In Box CONTROL TECHNIQUES/EMERSON NIDEC SP1406 Variable Frequency Drive

NEW – Emerson Rosemount 3051 Series Pressure Transmitter 3051CG5A02A1AH2E5L4BC

Emerson Ovation 1C31189G01 Speed Detector

Emerson CT SP1404 inverter new

New Ge / EMERSON PLC A/I module IC695ALG616

Tested Emerson CT UNI3402 Inverter

EMERSON VE4012S2B1 Module

EMERSON VE4012S2B1 Module

M-series Intrinsically Safe I/O

Features full system modularity

Reduces system footprint

Decreases installation time and expense

Plug-and-play installation saves money

Phased installation saves time

Easy to use

This fail-safe design enables you to

initially install I.S.

Real-time, online equipment additions

VE4012S2B1

Introduction

DeltaV™ M-series Intrinsically Safe Input/Output (I.S. I/O)

provides the perfect solution to the precarious situation of

running I/O in hazardous areas. DeltaV I.S. I/O is a distributed

I/O system capable of withstanding Class I Division 2 and Zone II

environmental conditions. The I.S. I/O subsystem connects field

circuits and field devices to the DeltaV system. Intrinsically safe

ield circuits and field devices can enter Class I Division 1.

Zone 1. and Zone 0. The DeltaV I.S. I/O supports industry

standard AI, AO, DI, and DO, applications.

Benefits

Features full system modularity. The I.S. I/O subsystem

was designed to optimize your automation investment.

All components are fully modular and installable under power.

You add I/O interface carriers and I/O interfaces in groups of

8 channels, as you need them. The modular design enables

you to buy the exact amount of I/O cards and power/controllers

that you need. Add more DeltaV I/O as your system grows.

Reduces system footprint. The state-of-the-art form

factor design of the DeltaV I/O components enables you to

mount the I/O interface carrier in a junction box in the field.

You significantly reduce the footprint of your equipment

and free up valuable control room space for other uses.

Decreases installation time and expense. DeltaV Intrinsically

Safe I/O are native DeltaV I/O cards that are part of the

controller’s I/O subsystem. This eliminates the need for third

party barriers or interface mapping. Save even further on wiring

expenses by installing I.S. I/O in the field, close to the actual

EMERSON KL4103X1-BA1 CHARMs Smart Logic Solver Carrier

KL4103X1-BA1 CHARMs Smart Logic Solver

Carrier

Hazardous Atmosphere

II 3G Ex ec IIC Gc

FM19ATEX0173U

IECEx FMG 19.0019U

FM21UKEX0017U

CL. I Div. 2 GP. A,B,C,D

CL. I Zone 2 AEx/Ex ec IIC Gc

FM17CA0145U

FM17US0286U

Power Specifications

Input power redundant

Output power to

CHARMS

+24 VDC at 12.5 A

+24 VDC at 10 A

+6.3 VDC at 4 A

Environmental Specifications

Ambient Temperature -40 °C to +70 °C

KL4103X1-BA1

Shock

Vibration

Airborne

Contaminants

Relative Humidity

10g ½ Sinewave for 11msec

1mm Peak to Peak from 2 to

13.2Hz; 0.7g from 13.2 to 150Hz

ISA-S71.04 –1985 Airborne

Contaminants Class G3

5 to 95% Non-Condensing

Note: Refer to the product label for serial number

and location and date of manufacture.

Warning: This product has specific instructions for

installation, removal and operation in hazardous

areas. Refer to document 12P5403 “DeltaV

Electronic Marshalling Digital Automation System

(CHARM I/O Subsystem) Zone 2 Installation

Instructions”. Other installation instructions are

available in the ” DeltaV S-series and CHARMs

Hardware Installation” manual.

Removal and Insertion

This unit cannot be removed or inserted with system

power energized unless the area is known to be

non-hazardous.

Maintenance and Adjustment

This unit contains no user serviceable parts and

should not be disassembled for any reason.

Calibration is not required.

EMERSON P188.R2 Industrial interface module

The Emerson P188.R2 is a versatile industrial interface module designed for various applications in industrial automation. Here are some key features:

HART Communication: Supports HART protocol for digital communication with field devices, allowing for real-time data exchange and diagnostics.

Modular Design: Can be integrated into control cabinets or automation equipment, enabling multi-channel parallel signal transmission.

Temperature Range: Operates effectively within a temperature range of -20°C to +70°C, making it suitable for harsh industrial environments.

Signal Integrity: Features multi-stage filtering circuits to ensure high signal transmission integrity and reduce interference.

Pressure Measurement: The P188.R2 also includes a pressure transmitter that offers reliable measurement of gauge, absolute, or differential pressure, making it ideal for critical process applications.

EMERSON CONTROL   TECHNIQUES UNIDRIVE M700-054 00300 A
Emerson Control Techniques Nidec FM-4E   Servo Control Module 960496-02
New SK3202 Emerson Commander SK AC   Variable Speed Drive, 240V, 15KW
EMERSON 3144PD1A2K5M5 Pressure   Transmitter
EMERSON 3051TG5A2B21AS5B4E5M5 PRESSURE   TRANSMITTER
EMERSON EV6000-4T0022G-H2A Inverter, FOR   PARTS/ REPAIR
NEW SURPLUS EMERSON OVATION 5X00063G01   HART ANALOG OUTPUT MODULE
NEW Emerson Rosemount 2051 Series Flow   Meter Pressure Transmitter R2051C4789580
Surplus Emerson CMFS015M319N2BMECZZ Micro   Motion Mass Flow Sensor
EMERSON GUBB33A ENCLOSURE
New Emerson Deltav 12P4474X022   RM100-EM-8TX Network Module KJ1611X1-GA1
Emerson BLM-8500-4 Servo Motor 460V   3000rpm BLM85004
Emerson Control Techniques Commander   Model: SK2403-029-1/ Freq In/Out: 50/
Emerson / Control Techniques Epsilon   EP209-P00-ENR0, NEW, WITH NDA Shipping!
NEW EMERSON LSN20 DELTAV 6-PORT SAFETY   NETWORK SWITCH LSN20-6TX2MM-ES
EMERSON iMP1-3Q0-3W0-1L0-00 Power Supply

EMERSON VE3008 CE3008 KJ2005X1-MQ1 12P6381X042  MQ Controller

EMERSON VE3008 CE3008 KJ2005X1-MQ1 12P6381X042  MQ Controller

Hazardous Atmosphere

II 3G Ex nA IIC Gc

FM12ATEX0090U

IECEx FMG 12.0035U

Power Specifications

Local Bus Power

+5 VDC at 1.4 A

Environmental Specifications

Ambient

Temperature

Shock

Vibration

Airborne

Contaminants

KJ2005X1-MQ1

Relative Humidity -40°C to +70°C

10g ½ Sinewave for 11msec

1mm Peak to Peak from 2 to 13.2Hz;

0.7g from 13.2 to 150Hz

ISA-S71.04 –1985 Airborne

Contaminants Class G3

5 to 95% Non-Condensing

Note: Refer to the product label for serial number

and location and date of manufacture.

Warning: This product has specific instructions for

installation, removal and operation in hazardous

areas.  Refer to document 12P2046 “DeltaV™

Scalable Process System Zone 2 Installation

Instructions”.   Other installation instructions are

available in the “DeltaV™ M-Series Hardware

Installation and Reference” manual.

The communications network connected to the

DeltaV Remote Interface Unit must not be

connected to a source that generates or contains

under normal conditions a potential in excess of 60

VAC or 75 VDC.

Removal and Insertion

This unit cannot be removed or inserted with system

power energized unless the area is known to be

non-hazardous.

Maintenance and Adjustment

This unit contains no user serviceable parts and

should not be disassembled for any reason.

Calibration is not required.

KJ2005X1-MQ1

Search for products

Back to Top
Product has been added to your cart
phone: +86 18150137010
to whats
+8618150137010
to whats
+8618150137010
email: industrialists.yan@gmail.com