MM2-2FXM3/2TX1

Industrial Networking:Industrial Ethernet:MICE:ETHERNET / Fast-ETHERNET Media

Modules

Product description

Description

Port type and quantity

Media module for MICE Switches (MS…),

100BASE-TX and 100BASE-FX multi-mode F/O

2 x 100BASE-FX, MM cables, MTRJ sockets,

2 x 10/100BASE-TX, TP cables, RJ45 sockets, auto-crossing, auto-negotiation,

auto-polarity

Type

Order No.

MM2-2FXM3/2TX1

943 720-101

Network size – length of cable

Twisted pair (TP)

Multimode fiber (MM) 50/125 µm

0 -100 m

0 – 5000 m,

8 dB link budget at 1300 nm,

A = 1 dB/km, 3 dB reserve, B = 800 MHz x km

Multimode fiber (MM) 62.5/125 µm

Power requirements

0 – 4000 m,

11 dB link budget at 1300 nm,

A = 1 dB/km, 3 dB reserve, B = 500 MHz x km

Operating voltage

Power consumption

power supply via the backplane of the MICE switch

5 W

MM2-2FXM32TX1

Service

Diagnostics

Ambient conditions

LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port,

LED test)

Operating temperature

Storage/transport temperature

0 ºC to +60 ºC -40 ºC to +70 ºC

Relative humidity (non-condensing)

MTBF

10% to 95%

48.7 years; MIL-HDBK 217F: Gb 25 ºC

Mechanical construction

Dimensions (W x H x D)

Mounting

38 mm x 134 mm x 77 mm

DIN Rail 35 mm

Weight

Protection class

170 g

IP 20

Mechanical stability

IEC 60068-2-27 shock

IEC 60068-2-6 vibration

15 g, 11 ms duration, 18 shocks

MM2-2FXM32TX1

1 mm, 2 Hz – 13.2 Hz, 90 min.; 0.7g, 13.2 Hz – 100 Hz, 90 min.; 3.5 mm, 3 Hz – 9

Hz,

10 Zyklen, 1 Oktave/min.; 1g, 9 Hz – 150 Hz, 10 Zyklen, 1 Oktave/min.

EMC interference immunity

EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge

EN 61000-4-3 electromagnetic field

10 V/m (80 – 1000 MHz)

EN 61000-4-4 fast transients (burst)

EN 61000-4-5 surge voltage

2 kV power line, 1 kV data line

power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line

EN 61000-4-6 conducted immunity

EMC emitted immunity

3 V (10 kHz – 150 kHz), 10 V (150 kHz – 80 MHz)

FCC CFR47 Part 15

EN 55022

FCC CFR47 Part 15 Class A

EN 55022 Class A

Safety of industrial control equipment

cUL 508 (E175531)

Hazardous locations

cUL 1604 Class 1 Div 2 (E203960)

Germanischer Lloyd

Scope of delivery and accessories

Germanischer Lloyd (43 109-02 HH)

Scope of delivery

Accessories to order separately

Module, operating manual

ML-MS2/MM labels