Call us 24/7+86 18150137010
Welcome to Industrial Control Trading Co., Ltd. Email: itadcs@163.com Whatsapp:+86-17750137010
Call us 24/7+86 18150137010

HIMA F7553 Digital input module

Hima F7553 Coupling Module

Manufacturer: HIMA

Part Number: F7553

Product Type:Digital input module

Description

The HIMA F7553 is a high-performance safety-related digital input module designed for use in critical applications where reliability and safety are paramount.

It is part of the HIMA HIMax safety system, which is used in various industries, including process control, oil and gas, and power generation, to ensure the safe operation of industrial processes.

F7553

Key Features

Safety-Critical Design: Engineered for use in environments where safety is critical.

High Reliability: Robust design to ensure long-term reliability and availability.

Flexible Configuration: Can be configured to meet specific application requirements.

Advanced Diagnostics: Comprehensive diagnostic capabilities to monitor system health and performance.

Integration: Seamless integration with other HIMA HIMax modules and systems.

Specifications

Electrical Specifications

Input Voltage: 24V DC

Input Channels: 16 digital input channels

Input Range: 0 to 30V DC

Input Response Time: 5ms

Environmental Conditions

Operating Temperature Range: -40°C to +70°C

Storage Temperature Range: -40°C to +85°C

Relative Humidity: 5% to 95% non-condensing

HIMA F7126 Power supply module

F 7126: Power supply module

Input voltage 24 V DC, output voltage 5 V DC

for PES H51q

The module supplies automation systems with 5 V DC from a main supply

of 24 V DC. It is a DC/DC converter with safe isolation between input and

output voltage. The module is equipped with overvoltage protection and

current limitation. The output is short circuit proof.

On the front plate there are a test socket and a potentiometer for adjusting

the output voltage.

To avoid unbalanced load with redundant use of the power supply F 7126

the difference between their output voltages may not be more than

F7126

0.025 V.

Operating data

Primary fuse

Output voltage

factory adjustment

Output current

Current limitation

Overvoltage protection

Efficiency rate

Interference

Space requirement

24 V DC, -15 … +20 %, rpp < 15%

6.3 A träge

5 V DC ± 0.5V adjustable without steps

5.4 V DC ± 0.025 V

10 A

approx. 13 A

set to 6.5 V/ ± 0.5V

≥ 77%

Limit class B

according to VDE 0871/0877

8 TE

F8627X/F8628X HIMA

F8627X/F8628X

The safe decision. productnews The new communication modules enable the programming of the CPUs with ELOP II via Ethernet.

These are used with the CPUs which are also new: F 8650X/F 8652X (safe CPU for H51q/H41q systems) F 8651X/F 8653X (non-safe CPU for H51q/H41q systems)

The already existing communication modules F 8627 and F 8628 are still available in the product portfolio.

Issue March 2006_Page 1/2 Applications/Accompanying products Part numbers/Delivery date F 8627X: 98 4862765 F 8628X: 98 4862865 Delivery date: immediately 2 new communication modules for H41q/H51q systems • F 8627X: Communication module for the protocols safeethernet and OPC DA via HIMA OPC server New: OPC A&E via HIMA OPC server, MODBUS-TCP slave and ELOP II programming via Ethernet (from ELOP II V. 4.1) Function Even more protocols! F8627X/F8628X Dimensions and weight • F 8628X: Communication module for the protocol Profibus DP slave New: ELOP II programming via Ethernet (from ELOP II V. 4.1) 19-inch module for H41q/H51q systems 3 height units (HU), 3 x 44.45 mm 4 width units (WU), 4 x 5.08 mm

Name Firma Abteilung Straße PLZ, Ort Land Telefon Telefax E-Mail FAX-ANTWORT Bitte senden Sie mir mehr Informationen Bitte kontaktieren Sie mich bzgl.

eines Angebotes Bitte rufen Sie mich zurück Antworten bitte per Fax an Ihren Ansprechpartner F 8627X: • 100 Base-T interface, RJ45 • Safe communication (mono configuration or redundant) between H41q/H51q systems via safeethernet Issue March 2006_Page 2/2 Part numbers/Delivery date F 8627X: 98 4862765 F 8628X: 98 4862865 Delivery date: immediately Detailed functions/Advantages 96 9918081 0306 © by HIMA Paul Hildebrandt GmbH + Co KG..

HIMax TECHNICAL FACTS X Series

TECHNICAL FACTS

HIMax

HIMax is a flexible platform for critical production processes that you can never afford to have go down.

HIMax adapts to all I/O-count, response-time and fault-tolerance requirements as well as centralized

and distributed applications. HIMax delivers availability for life by enabling uninterrupted system operation

throughout your plant’s life cycle. Hardware and software changes can be performed without system

interruption. Alternative CPU modules make HIMax suitable for meeting high performance and critical

control requirements as well as for use in small and mid-sized safety applications.

X

HIMax Modules Type Description

Centralmodules

Processormodule X-CPU01 Forhighperformanceandcriticalcontrolrequirements

Processormodule X-CPU31 Forsmallandmid-sizedsafetyapplications

Systembusmodule X-SB01

Communicationmodule X-COM01 4xRJ-45.2×9-poleD-Sub,upto6differentprotocols

Input/outputmodules

Input modules

Digital inputmodule X-DI6401 64channels,24VDC,SIL3

Digital inputmodule X-DI6451 64channels,24VDC

Digital inputmodule X-DI3201 32channels,24VDC,SIL3

Digital inputmodule X-DI3202 32channels,8.2VDC,proximityswitch, linemonitoring,SIL3

Digital inputmodule X-DI3203 32channels,48VDC,SIL3

Digital inputmodule X-DI3204 32channels,24VDC,SOE,SIL3

Digital inputmodule X-DI3205 32channels,8.2VDC,proximityswitch, linemonitoring,SOE,SIL3

Digital inputmodule X-DI3251 16channels,120VAC,SIL3

Digital inputmodule X-DI3252 32channels,8.2VDC,proximityswitch, linemonitoring

Digital inputmodule X-DI1601 16channels,120VAC,SIL3

Analoginputmodule X-AI1651 16channels,0/4…20mA,± 280mV,galvanicallyisolated,thermocoupleTC,Pt100

Analoginputmodule X-AI3201 32channels,4…20mA, linemonitoring,SIL3

Analoginputmodule X-AI3202 32channels,4…20mA, linemonitoring,SOE,SIL3

Analoginputmodule X-AI3251 32channels,0/4…20mA, linemonitoring

Countermodule X-CI2401 24channels,0…20kHz,SIL3

Countermodule X-CI2451 24channels,0…20kHz

Output modules

X

Digitaloutputmodule X-DO3201 32channels,24VDC,0.5A,short-circuitmonitoringLS, individualchannelshut-off,SIL3

Digitaloutputmodule X-DO3251 32channels,24VDC,0.5A,protectedoutputs,groupshut-off

Digitaloutputmodule X-DO2401 24channels,24VDC,0.5A, linemonitoringLS/LB, individualchannelshut-off,SIL3

Digitaloutputmodule X-DO2402 24channels,48VDC,0.5A, linemonitoringLS/LB, individualchannelshut-off,SIL3

Relayoutputmodule X-DO1201 12channels,230VAC/DC,currentmeasurement,cyclecounting,SIL3

Digitaloutputmodule X-DO1202 12channels,24VDC,2A,short-circuitmonitoringLS, individualchannelshut-off,SIL3

Relayoutputmodule X-DO1251 12channels,230VAC/DC

Analogoutputmodule X-AO1601 16channels,4…20mA,pairwisegalvanicallyisolated

Analogoutputmodule X-AO1651 16channels,4…20mA

Furthermodules

HARTcommunicationmoduleX-HART320132modems,SIL3.X-AI3201.X-AI3202.X-AI3251.X-AO1601.X-AO1651

Overspeedtripmodule X-MIO7/601 3counter,4digital input,5digitaloutput,1relaychannel,SIL3

Dimensions

Sizeofmodules All 310 x 29 x 230 mm

Highlights

• XMRarchitectureandintegratedredundancymanagementdeliver“availabilityforlife”

• Uniquecommon-causeprotection

• Allchanges,additionsandmaintenanceproceduresarepossiblewithoutstopping

aHIMaxsystem

• CPUself-educateswhenprocessormoduleisreplaced

• Prooftestscanbeconductedonline

• Storesupto2.500diagnosticentriesintheprocessormoduleand500entriesper

I/Omoduleautomatically

• Multitasking–runupto32userprogramssimultaneously

• Sequenceofevent(SOE),storagefor5.000events,1msresolutionquality

• Redundantintegratedandprotectedpowerdistribution

• Twoorthreewiringinputs/outputsperchanneltohelpeliminateadditionalwiring

• Remoterackfunctionalityenablesstartopology

• HIMax–HIMatrixPES,redundantlinkviaSafeEthernet

• OptimizeprocesssimulationandoperatortrainingwiththeHIMaxSafetySimulatorX-OTS

HIMA F3330 8-Fold Output Module

HIMA F3330 8-Fold Output Module
Product Type:8 fold Output module, safety related

Internal Voltage Drop:Max.  2 V at 500 mA load

Undervoltage Tripping:At 16 V

Operating Data:5 V DC = 110 mA, 24 V DC = 180 mA in additional load

Weight:0.25 kg

Brand:HIMA

Model:F3330

F3330

The HIMA F3330 is a highly reliable 8-fold output module specifically designed for safety-related applications in industrial environments.

This module ensures consistent and dependable performance even under demanding conditions.

With its robust design and precise specifications, the HIMA F3330 provides superior protection and functionality.

Its low internal voltage drop and undervoltage tripping feature guarantee optimal operation.

Additionally, the HIMA F3330 comes with a lightweight design, weighing just 0.

25 kg, making it easy to integrate into existing systems without compromising on performance or safety

F3330

HIMA F3236 Digital input module

HIMA F3236 Digital input module

For the serial interface only the bus station no. 1-31 can be set.

Within an Ethernet network the bus station no. can be set from 1 to 99. Therefore the switches

S1-6/7 must be set in addition to the switches S1-1/2/3/4/5.

The number of the communication partners within a network is still limited to 64.

This enhanced setting of the bus station no. is only possible from operating system BS41q/51q

V7.0-8 (05.31) of the central module.

Applications with the communication module F 8627X:– connection of the central module to a PADT (ELOP II TCP)– connection to other communication partners within an Ethernet network (safeethernet,

Modbus TCP)

The communication runs from the central module via the backplane bus to the communication

module F 8627X and from the Ethernet ports of the F 8627X into the Ethernet network and vice

versa.

Special features of the central module:– Self-education: from operating system BS41q/51q V7.0-8 (05.31)– ELOP II TCP: from operating system BS41q/51q V7.0-8 (05.31)

Further informations about the bus station no., ELOP II TCP, loading of operating systems and

application programs (self-education) et al. corresponding to the central module you will find in

the data sheet of the F8627X as well as the operating system manual of H41q/H51q and the

safety manual of H41q/H51q

Diagnostic display of the central module– Four digit alphanumerical display,– two LEDs for the general display of errors (CPU for the central modules, IO for the testable

input/output modules),– two toggle switches to request detailed error information,– push-button ACK resets the error indication;

in failure stop ACK behaves like restarting the system.

For further information on the diagnostic display and lists of error codes, refer to the documen

tation “Functions of the operational system BS 41q/51q” (also on ELOP II CD).

Notes for start-up and maintenance– Lifetime of the buffer battery (without voltage feeding):

1000 days at TA = 25 °C

200 days at TA = 60 °C– It is recommended to change the buffer battery (CPU in operation) at the latest after 6

years, or with display BATI within three months

(Lithium battery, e.g. type CR 2477N, HIMA part no. 44 0000018)– Check the bus station no. and transmission rate at switch S1 for correct settings– Important: When upgrading an F 8650 to an F 8650X module the fan concept has also to

be changed!

HIMA F 8650X Central module

F 8650X: Central module

Use in the PES H51q-MS, -HS, -HRS,

Central module with two clock-synchronized microprocessors

Microprocessors

Clock frequency

Memory per microprocessor

Operating System

User program

Data

INTEL 386EX, 32 bits

25 MHz

Flash-EPROM 1 MB

Flash-EPROM 1 MB *

SRAM 1 MB *

F 8650X

F 8650X

* Degree of utilization depending on operating system version

Interfaces

Diagnostic display

Shutdown on fault

Construction

Space requirement

Operating data

Two serial interfaces RS 485 with electric isolation

Four digit matrix display with selectable information

Safety-related watchdog with output 24 V,

loadable up to 500 mA, short-circuit proof

Two European standard PCBs,

one PCB for the diagnostic display

8 SU

5 V / 2 A

F 8650X

For the serial interface only the bus station no. 1-31 can be set.

Within an Ethernet network the bus station no. can be set from 1 to 99. Therefore the switches

S1-6/7 must be set in addition to the switches S1-1/2/3/4/5.

The number of the communication partners within a network is still limited to 64.

This enhanced setting of the bus station no. is only possible from operating system BS41q/51q

V7.0-8 (05.31) of the central module.

Applications with the communication module F 8627X:– connection of the central module to a PADT (ELOP II TCP)– connection to other communication partners within an Ethernet network (safeethernet,

Modbus TCP)

The communication runs from the central module via the backplane bus to the communication

module F 8627X and from the Ethernet ports of the F 8627X into the Ethernet network and vice

versa.

F 8650X

Special features of the central module:– Self-education: from operating system BS41q/51q V7.0-8 (05.31)– ELOP II TCP: from operating system BS41q/51q V7.0-8 (05.31)

Further informations about the bus station no., ELOP II TCP, loading of operating systems and

application programs (self-education) et al. corresponding to the central module you will find in

the data sheet of the F8627X as well as the operating system manual of H41q/H51q and the

safety manual of H41q/H51q

Diagnostic display of the central module– Four digit alphanumerical display,– two LEDs for the general display of errors (CPU for the central modules, IO for the testable

input/output modules),– two toggle switches to request detailed error information,– push-button ACK resets the error indication;

in failure stop ACK behaves like restarting the system.

For further information on the diagnostic display and lists of error codes, refer to the documen

tation “Functions of the operational system BS 41q/51q” (also on ELOP II CD).

Notes for start-up and maintenance– Lifetime of the buffer battery (without voltage feeding):

1000 days at TA = 25 °C

200 days at TA = 60 °C– It is recommended to change the buffer battery (CPU in operation) at the latest after 6

years, or with display BATI within three months

(Lithium battery, e.g. type CR 2477N, HIMA part no. 44 0000018)– Check the bus station no. and transmission rate at switch S1 for correct settings– Important: When upgrading an F 8650 to an F 8650X module the fan concept has also to

be changed!

HIMA K9203A Rack Fan

K 9203A Rack Fan

The K 9203A rack fan is a circulation fan equipped with the following components:

3 axial fans

Redundant supply

Fan operation monitoring

Voltage monitoring Application: Forced ventilation of 19” rack installations. Air is sucked in below the

circulation fan and is blown out from the top. The axial fans are positioned to align with HIMA

19” subracks.

Installation site: Anywhere within the 19” field

Specifications:

Material

Operating data

Air flow

Rated speed

Sound pressure level

Lifetime at 40 °C

Space requirement

Weight

Ambient temperature

Aluminum, anodized

24 VDC, -15…+20 %, rpp ≤ 15 %

K9203

max. 750 mA

300 m3 per hour

2800 min-1

approx. 55 dB(A)

62 500 h

19”, 1 RU, depth 215 mm

1.8 kg -20…+70 ºC

Connector plug:

The connector plug is used to connect the cabinet fan to the power supply. To increase

availability, terminal 3 may be connected to a redundant power supply. Optical and acoustic

detectors can be connected to terminals 4…6.

K9203

The following wires can be connected:

Wire

Cross-section

Connection

Single-wire

0.08…2.5 mm²

Finely stranded

Spring-cage terminal *

0.25…1.5 mm²

Finely stranded with wire

end ferrule

Spring-cage terminal *

0.25…2.5 mm²

Spring-cage terminal *

* Actuation tool (screwdriver slotted 3.5 x 0.5 mm)

HIMA HIMatrix F3 AIO 8/4 01 Manual controller

HIMA HIMatrix F3 AIO 8/4 01 is a high-performance safety I/O module designed by HIMA Company, which is specially developed for Safety Instrumentation System (SIS) in the field of industrial automation. This module has the following features:

Modular design: adopt compact metal shell, support flexible configuration, and facilitate installation and maintenance.
High safety level: it conforms to SIL 3 certification and is suitable for key safety applications in process industry.
Input/output channels: 8 analog input channels and 4 analog output channels are provided, and various communication protocols, such as SafeEthernet, are supported to ensure the security of data transmission.
Strong adaptability to working environment: the working temperature range is -20℃ to +60℃ and the humidity range is 5% to 95%RH, which is suitable for harsh environment.
Multifunctional: Support self-diagnosis function, find and report faults in time, and improve the reliability of the system.
Application: Widely used in petrochemical, electric power, metallurgy, nuclear power and offshore platforms and other industrial fields that need high safety.
The user manual of this module provides detailed installation, configuration and operation guidelines, including safety precautions, startup steps, troubleshooting and other contents to help users use and maintain the equipment correctly.
HIMA is a leading brand in the field of industrial safety system, focusing on safety instrument system (SIS), emergency shutdown system (ESD) and combustion management system (BMS). The following are HIMA’s model series and similar products related to HIMatrix F3 AIO 8/4 01:

HIMatrix F3 series (modular safety controller)
Features: Modular design, high availability, SIL 3/SIL 4 certification, suitable for process industry.
Related models:
F3 AIO 8/4 01: 8 analog inputs+4 analog outputs.
F3 di 16/8 01: 16 digital inputs+8 digital outputs.
F3 AI16 01: 16 analog inputs.
F3 do 16 01: 16 digital outputs.
F3 RTD 8 01: 8 RTD (thermal resistance) inputs.

    HIMA X-FAN 18 03 High-efficiency cooling plate fan

    HIMA X-FAN 18 03 is an efficient cooling plate fan, which is specially designed for industrial control equipment and electronic circuit boards. It has the characteristics of high airflow, low noise and high reliability. Its main parameters include:

    Power supply voltage: 24 VDC, power consumption is 10 W.
    Fan speed: 4000 RPM.
    Air volume: 300 CFM (about 170 m/h).
    Noise level: 40 dBA.
    Size: 115 mm x 115 mm x 32 mm.
    Operating temperature range:-20 c to 60 c.
    Protection grade: IP65.
    The fan is widely used in industrial automation system, electronic equipment heat dissipation, safety instrument system and other fields, such as petroleum, natural gas, electric power, metallurgy and other industries. In addition, it is also suitable for cooling electronic equipment such as computers, servers and network equipment.
    HIMA X-FAN 18 03 is a Panel Fan of HIMA Company, which is mainly used for heat dissipation of industrial control cabinets, safety systems (such as safety PLC) or electronic equipment. The following are some related models and characteristics of HIMA X-FAN series:

    1. HIMA X-FAN 18 series (common model)
      X-FAN 18 03

    Voltage: 24 V DC
    Size: 115 × 115 × 32 mm
    Air volume: ~ 170 m/h
    Rotational speed: 4000 RPM
    Protection grade: IP65
    X-FAN 18 05

    Voltage: 24 V DC
    Size: 120 × 120 × 38 mm (or other variants)
    Higher air volume, suitable for cooling of larger cabinets.
    X-FAN 18 10

    Voltage: 230 V AC
    Suitable for AC power supply environment of industrial cabinets

    1. HIMA X-FAN 12 series (small fan)
      X-FAN 12 02
      Voltage: 24 V DC
      Size: 80 × 80 × 25 mm
      Suitable for compact control cabinet
    2. HIMA X-FAN 24 series (high-power fan)
      X-FAN 24 05
      Voltage: 24 V DC/230 V AC
      Size: 172 × 150 × 51 mm
      Higher air volume, suitable for large cabinets or high temperature environment.
    3. HIMA X-FAN Ex (explosion-proof)
      X-fan ex xx (the specific model may be different)
      ATEX/IECEx certification, suitable for hazardous areas (such as petroleum and chemical industries).
    4. HIMA X-COOL (integrated cooling system)
      X-COOL xx (such as X-COOL 10)
      Activ

    Search for products

    Back to Top
    Product has been added to your cart
    phone: +86 18150137010
    to whats
    +8618150137010
    to whats
    +8618150137010
    email: industrialists.yan@gmail.com