Hirschmann MS4128-L2P ATEX Power MICE Switching Module

Hirschmann MS4128-L2P is a modular industrial Ethernet switch, which is specially designed to meet the needs of industrial automation and network communication. Based on MICE series, this switch supports flexible port configuration and multiple functions, and is suitable for various industrial application scenarios.

Product features:

Port configuration: MS4128-L2P provides 4 Gigabit ports (10/100/1000 Mbps) and 24 fast Ethernet ports (10/100 Mbps), which can be increased to 28 ports by expanding the backplane.
Modular design: support the insertion of various media modules (such as SFP module or RJ45 module) to realize flexible network topology, including linear, ring and star topology.
Three-layer routing function: support three-layer routing protocol, which can realize more complex network management.
Security and reliability: It has port security, access control, VLAN, SNMP and other security functions, and has passed many international certifications (such as CE, FCC, IEC 60950-1, etc.) to ensure stable operation in harsh environment.
Environmental adaptability: wide working temperature range (0℃ to +60℃), supporting dust-proof, moisture-proof, anti-electromagnetic interference and other characteristics, suitable for chemical industry, energy, transportation and other industries.
Application scenario:
MS4128-L2P is widely used in industrial automation, traffic monitoring, tunnels and airports, especially in the environment that requires high reliability and flexibility.

Summary:
Hirschmann MS4128-L2P is a powerful and flexible industrial-grade switch. With its modular design, rich port selection and strong network management ability, it can meet the requirements of modern industrial networks for efficiency, reliability and security.

Hirschmann MS4128-L2P 943009101 MICE Managed Ethernet Switch

Device description

The PowerMICE devices consist of a switch with media modules that can be
plugged into it. The devices have 4 slots for 10/100 Mbit/s media modules
and 1 slot for 1 Gigabit module. The slot for the Gigabit module supports 2
Gigabit ports. The expansion module provides you with 2 additional slots for
10/100 Mbit/s media modules. Each media module provides you with 2 to 4
ports for connecting network segments.
The PowerMICE devices are designed for the special requirements of
industrial automation. They meet the relevant industry standards, provide
very high operational reliability, even under extreme conditions, and also
provide long-term reliability and flexibility.
The devices work without a fan.
The voltage is supplied redundantly.
The following installation options are available:
 simply snapping them onto a DIN rail
You can choose various media to connect terminal devices and other
infrastructure components:
 twisted pair cable
 multimode F/O
 singlemode F/O
The twisted pair ports support:
 Autocrossing
 Autonegotiation
 Autopolarity
The following software variants are available:
 MICE MS4128-L2P: Layer 2 Professional
 MICE MS4128-L3E: Layer 3 Enhanced
 MICE MS4128-L3P: Layer 3 Professional
There are convenient options for managing the device. Administer your
devices via:
 a Web browser
 Telnet
 management software (e.g. Industrial HiVision)
 a V.24 interface (locally on the device)
The ring redundancy concept allows the network to be reconfigured quickly
after a failure.

Product configuration data can be provided by:
 diagnosis displays
 displaying the operating parameters
 large label areas
The clear division of the diagnosis displays and the connection level allows
you to view the LEDs easily.

Hirschmann MM20-P9P9T1T1SAHH Media Module: Efficient Choice of Industrial Ethernet Solutions

The naming of copyrighted trademarks in this
manual, even when not specially indicated,
should not be taken to mean that these names
may be considered as free in the sense of the
trademark and tradename protection law and
hence that they may be freely used by anyone.
© 2023 Hirschmann Automation and Control
GmbH
Manuals and software are protected by copyright. All rights reserved. The copying, reproduction, translation, conversion into any electronic medium or machine scannable form is
not permitted, either in whole or in part. An
exception is the preparation of a backup copy
of the software for your own use.
The performance features described here are
binding only if they have been expressly agreed when the contract was made. This document was produced by Hirschmann
Automation and Control GmbH according to
the best of the company’s knowledge. Hirschmann reserves the right to change the contents
of this document without prior notice. Hirschmann can give no guarantee in respect of the
correctness or accuracy of the information in
this document.
Hirschmann can accept no responsibility for
damages, resulting from the use of the network
components or the associated operating software. In addition, we refer to the conditions of
use specified in the license contract.
You can get the latest version of this manual
on the Internet at:
https://www.doc.hirschmann.com
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany
Safety instructions
Certified usage
Please observe the following:
z Warning!
The device may only be employed for
the purposes described in the catalog
and technical description, and only in
conjunction with external devices and
components recommended or approved by Hirschmann. The product can
only be operated correctly and safely if
it is transported, stored, installed and
assembled properly and correctly. Furthermore, it must be operated and serviced carefully.
Supply voltage
To be supplied by a NEC Class 2 power
supply via MICE switch module.
For Power over Ethernet modules: Connect a
NEC Class 2 power supply only.
Use +60/75 °C or +75 °C copper (CU) wire
only.
Use a potential-free supply voltage only.
Ground the supply voltage otherwise via GND.
A positive grounding of the supply voltage is
not permitted.
Shielding Ground
Note: The shielding ground of the connectable
twisted pairs lines is connected to the front
panel as a conductor.
□ Beware of possible short circuits when
connecting a cable section with conductive
shielding braiding.
Casing
z Warning!
Only technicians authorized by
Hirschmann are permitted to open the
casing.
□ Make sure that the electrical installation
meets local or nationally applicable safety
regulations.
z Warning!
Never insert pointed objects (thin
screwdrivers, wires, etc.) into the
inside of the subrack! This especially
applies to the area behind the socket
connectors. Failure to observe this
point may result in injuries caused by
electric shocks.
General Safety Instructions
□ Particular attention is to be paid to all
warnings and items of information relating
to safety.
□ Peripheral equipment must be suitable for
the location in which it is used.
z Warning!
Any work that may have to be performed on the electrical installation
should be performed by fully qualified
technicians only.
Note: LED or LASER components in compliance with IEC 60825-1: CLASS 1 LASER PRODUCT for Cat. No. having the following fiber
optic modules (identified by module code)
incorporated: S2, S4, E2, L2, G2, Z6, O7.
CLASS 1 LED PRODUCT for Cat. No. having
the following fiber optic modules (identified by
module code) incorporated: M2, M3, M4, F4.
Refer to the product code description in chapter 7.
ESD guidelines
The modules are equipped with electrostatically sensitive components. These can be destroyed, or their life cycles reduced, by the
effects of an electrical field or by a charge
equalization if the connections are touched.
You will find information about electrostatically
endangered assemblies in
DIN EN 61340-5-1 (2007-08) and
DIN EN 61340-5-2 (2007-08).
CE marking
The devices comply with the regulations contained in the following European directive(s):
2014/30/EU (EMC)
Directive of the European Parliament and the
council for standardizing the regulations of
member states with regard to electromagnetic
compatibility.
2011/65/EU (RoHS) and 2015/863/EU (RoHS)
Directive of the European Parliament and of
the Council on the restriction of the use of certain hazardous substances in electrical and
electronic equipment.
2014/34/EU (ATEX)
Directive of the European Parliament and of
the Council on the harmonisation of the laws of
the Member States relating to equipment and

protective systems intended for use in potentially explosive atmospheres.
Note: The ATEX Directive applies exclusively
to the device variants labeled with an ATEX
certificate number: DEKRA 13ATEX0019 X
In accordance with the above named EU directive(s), the EU conformity declaration will be at
the disposal of the relevant authorities at the
following address:
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
You find the EU declaration of conformity as
PDF file for downloading on the Internet at:
https://www.doc.hirschmann.com/certificates.ht
ml
The product can be used in living areas (living
area, place of business, small business) and in
industrial areas.
– Interference immunity: EN 61000-6-2
– Emitted interference: EN 55032 Class A
z Warning!
This is a class A device. This device
can cause interference in living areas,
and in this case the operator may be
required to take appropriate measures.
The assembly guidelines provided in
these instructions must be strictly
adhered to in order to observe the
EMC threshold values.

Search for products

Back to Top
Product has been added to your cart
phone: +86 18150137010
to whats
+8618150137010
to whats
+8618150137010
email: industrialists.yan@gmail.com